Sun StorageTek 3320 SCSI Array
| Цена: |
по запросу |
| Наличие: |
Под заказ
|
| Артикул: | StorageTek 3320 | | Производитель: | Sun | |
|
Sun StorageTek 3320 SCSI Array
Specifications
|
Host interface: 320MB SCSI LVD |
|
Drives |
320MB SCSI 3.5 in. low profile |
|
Supported drives: 73GB 10K rpm; 73GB 15K rpm; 146GB 10K rpm, 146GB 15K rpm, 300GB 10K rpm |
|
Maximum number of host ports: 3x320MB SCSI host ports (without expansion trays); 2x320MB SCSI host ports (with 1 expansion tray); 1x320 MB SCSI host port (with 2 expansion trays) |
|
Maximum cable length: 12m | |
|
Total raw capacity |
73GB 10K rpm and 15K rpm HDDs - 876GB per 2U tray; expandable to 2.6TB per RAID array 146GB 10K rpm and 15K rpm HDDs - 1.72TB per 2U tray; expandable to 5.2TB per RAID array 300GB 10K rpm HDDs - 3.60TB per 2U tray; expandable to 10.8TB per RAID array | |
|
RAID configurations: Per tray: JBOD/expansion (no controller); single RAID controller; dual (mirrored) RAID controllers |
|
RAID levels: 0, 1, 1+0, 3, 5, 3+0, and 5+0 |
|
Max. LUNS: Up to 128 per RAID array |
|
Max. local and/or global hot spares: Up to 20 (RAID set and disk quantity dependent) per RAID array |
|
Cache size (read and write): 512MB per controller |
|
Cache battery backup: Up to 72 hours |
|
Cache write policy (user configurable): Write Backdefault; Write Throughdefault for single controller or on battery/controller failure |
|
Cache selectable block sizes: 32K (random file transfer); 128K (sequential file transfer) |
|
Included management software: Sun StorEdge Configuration Service; Sun StorEdge Diagnostic Reporter software |
|
Supported software |
Optional:
- Sun StorEdge Enterprise Storage Manager software
- Sun StorEdge Traffic Manager software
- Sun Cluster 3 software
- VERITAS NetBackup and VERITAS Volume Manager including DMP
- Sun Logical Volume Manager for the Solaris 9 Operating System
- Sun Solstice DiskSuite for the Solaris 8 Operating System
- Sun StorEdge Resource Management
- Sun StorEdge Utilization
- Sun StorEdge Performance Suites
| |
|
Servers |
All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers |
|
Supported HBAs |
Note: All non-Sun host bus adapters supported by third-party vendor.
- Sun Solaris Operating Systems 8, 9, 10 (SPARC-based)
HBAs: SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A
- Sun Solaris x86 9, 10
HBAs: (Sun Fire V60x, V65x, V20z, V40z) X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
- Red Hat Linux AS3.0
HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
- Novell SuSE Linux SLES9
HBAs: SG-XPCI2SCSI-LM320
- MS Windows NT EE 4.0/2000/2003
HBAs: X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
- Novell NetWare 5.1, 6.0, 6.5
HBA: Adaptec 39160; Adaptec 39320
- HP-UX 11i
HBA: HP A6829A
- IBM-AIX 5.1L
HBA: IBM SYM53C1010 |
|
Operating system |
- Sun Solaris Operating Environments 8, 9, 10, SPARC Platform Edition
- Solaris 10 operating system, x86 Platform Edition
- Red Hat Linux AS 3.0
- Microsoft Windows 2000 Advanced Server and Windows 2003 Server
- IBM AIX 5.1
- HP-UX 11i
- Novell Netware 5.1 and 6.5
- SUSE LINUX Enterprise Server 9.0, (32-bit and 64-bit)
| |
- Hot-swap RAID controllers with battery-backed mirrored 512MB cache, (with dual RAID controllers)
- Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant cooling fans
- Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
| |
|
Watts |
420W each (Dual hot-swap redundant power supplies) |
|
Operating voltage |
100 to 240 VAC, single phase |
|
AC Power Requirement: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz) |
|
AC Current per input: 100 to 240 VAC, 50 to 60 Hz, 5.07.1A |
|
DC Voltage: 48 or 60 VDC, 18A |
|
DC power |
36 to 75 VDC |
|
DC Current per input: 48 or 60 VDC, 18A | |
|
Temperature |
Operating: 5 deg C to 40 deg C (41 deg F to 104 deg F) Nonoperating: 40 deg C to 65 deg C (40 deg F to 149 deg F) |
|
Humidity |
Operating: 10 percent to 90 percent relative to 38 deg C Nonoperating: 0 percent to 90 percent relative to 27 deg C |
|
Altitude |
Operating: 30m to 3048m (100 to 10,000 ft.) Nonoperating: 30m to 12,192m (100 to 40,000 ft.) |
|
Shock |
Operating: 5.0 G, 11-ms, half-sine Nonoperating: 15.0 G, 11-ms, half-sine |
|
Vibration |
Operating: 0.2 G, 5500 Hz, swept-sine Nonoperating: 1.0 G, 5500 Hz, swept-sine |
|
Noise |
*LWAD = 6.6 bels * LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23 deg C | |
|
Meets or exceeds the following requirements: |
|
Safety |
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003 |
|
Emissions |
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark |
|
Harmonics |
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001 |
|
Immunity |
CSIPR 24 EN 55024 |
|
NEBS |
Ruggedized: NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386 | |
|
Dimensions (Height, Width, Depth): H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.) |
|
Weight |
(Fully Populated): 22.7 kg (50 lb.) | |
|
|