Sun StorageTek 3320 SCSI Array

Цена: по запросу
Наличие: Под заказ
Производитель:Sun
Sun StorageTek 3320 SCSI Array
Specifications
 
Standard Interfaces
Host interface: 320MB SCSI LVD
Drives
320MB SCSI 3.5 in. low profile
Supported drives: 73GB 10K rpm; 73GB 15K rpm; 146GB 10K rpm, 146GB 15K rpm, 300GB 10K rpm
Maximum number of host ports: 3x320MB SCSI host ports (without expansion trays); 2x320MB SCSI host ports (with 1 expansion tray); 1x320 MB SCSI host port (with 2 expansion trays)
Maximum cable length: 12m
 
Capacity
Total raw capacity
73GB 10K rpm and 15K rpm HDDs - 876GB per 2U tray; expandable to 2.6TB per RAID array
146GB 10K rpm and 15K rpm HDDs - 1.72TB per 2U tray; expandable to 5.2TB per RAID array
300GB 10K rpm HDDs - 3.60TB per 2U tray; expandable to 10.8TB per RAID array
 
Controller Card
RAID configurations:
Per tray: JBOD/expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
RAID levels: 0, 1, 1+0, 3, 5, 3+0, and 5+0
Max. LUNS: Up to 128 per RAID array
Max. local and/or global hot spares: Up to 20 (RAID set and disk quantity dependent) per RAID array
Cache size (read and write): 512MB per controller
Cache battery backup: Up to 72 hours
Cache write policy (user configurable): Write Back?default; Write Through?default for single controller or on battery/controller failure
Cache selectable block sizes: 32K (random file transfer); 128K (sequential file transfer)
Included management software: Sun StorEdge Configuration Service; Sun StorEdge Diagnostic Reporter software
Supported software
Optional:
  • Sun StorEdge Enterprise Storage Manager software
  • Sun StorEdge Traffic Manager software
  • Sun Cluster 3 software
  • VERITAS NetBackup and VERITAS Volume Manager including DMP
  • Sun Logical Volume Manager for the Solaris 9 Operating System
  • Sun Solstice DiskSuite for the Solaris 8 Operating System
  • Sun StorEdge Resource Management
  • Sun StorEdge Utilization
  • Sun StorEdge Performance Suites
 
Supported Platforms
Servers
All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers
Supported HBAs
Note: All non-Sun host bus adapters supported by third-party vendor.
  • Sun Solaris Operating Systems 8, 9, 10 (SPARC-based)
    HBAs: SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A
  • Sun Solaris x86 9, 10
    HBAs: (Sun Fire V60x, V65x, V20z, V40z) X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
  • Red Hat Linux AS3.0
    HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
  • Novell SuSE Linux SLES9
    HBAs: SG-XPCI2SCSI-LM320
  • MS Windows NT EE 4.0/2000/2003
    HBAs: X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
  • Novell NetWare 5.1, 6.0, 6.5
    HBA: Adaptec 39160; Adaptec 39320
  • HP-UX 11i
    HBA: HP A6829A
  • IBM-AIX 5.1L
    HBA: IBM SYM53C1010
Operating system
  • Sun Solaris Operating Environments 8, 9, 10, SPARC Platform Edition
  • Solaris 10 operating system, x86 Platform Edition
  • Red Hat Linux AS 3.0
  • Microsoft Windows 2000 Advanced Server and Windows 2003 Server
  • IBM AIX 5.1
  • HP-UX 11i
  • Novell Netware 5.1 and 6.5
  • SUSE LINUX Enterprise Server 9.0, (32-bit and 64-bit)
 
Reliability, Availability, Serviceability (RAS)
  • Hot-swap RAID controllers with battery-backed mirrored 512MB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
 
Electrical Requirements
Watts
420W each (Dual hot-swap redundant power supplies)
Operating voltage
100 to 240 VAC, single phase
AC Power Requirement: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
AC Current per input: 100 to 240 VAC, 50 to 60 Hz, 5.0?7.1A
DC Voltage: ?48 or ?60 VDC, 18A
DC power
?36 to ?75 VDC
DC Current per input: ?48 or ?60 VDC, 18A
 
Environment
Temperature
Operating: 5 deg C to 40 deg C (41 deg F to 104 deg F)
Nonoperating: ?40 deg C to 65 deg C (?40 deg F to 149 deg F)
Humidity
Operating: 10 percent to 90 percent relative to 38 deg C
Nonoperating: 0 percent to 90 percent relative to 27 deg C
Altitude
Operating: ?30m to 3048m (?100 to 10,000 ft.)
Nonoperating: ?30m to 12,192m (?100 to 40,000 ft.)
Shock
Operating: 5.0 G, 11-ms, half-sine
Nonoperating: 15.0 G, 11-ms, half-sine
Vibration
Operating: 0.2 G, 5?500 Hz, swept-sine
Nonoperating: 1.0 G, 5?500 Hz, swept-sine
Noise
*LWAD = 6.6 bels
* LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23 deg C
 
Regulations
Meets or exceeds the following requirements:
Safety
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003
Emissions
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
Harmonics
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity
CSIPR 24 EN 55024
NEBS
Ruggedized: NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
 
Dimensions and Weight
Dimensions (Height, Width, Depth): H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
Weight
(Fully Populated): 22.7 kg (50 lb.)