Standard Interfaces |
Host interface |
2 Gb Fibre Channel |
|
Drives |
3.5 in. low profile |
|
Supported drives |
Dual-ported active- active 2 Gb Fibre Channel 73 GB 15k rpm; 146 GB 10k rpm, 146 GB 15k rpm, 300 GB 10k rpm |
|
Maximum number of host ports |
Dual RAID controllers: 8x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays |
|
Maximum cable length |
250 m |
FC Tray (12 HDDs) and FC RAID Array (108 HDDs) Maximum Raw Storage Capacities |
73 GB HDDs |
876 GB per 2U tray; expandable to 7.8 TB per RAID array |
|
146 GB HDDs |
1.7 TB per 2U tray; expandable to 15.7 TB per RAID array |
|
300 GB HDDs |
3.6 TB per 2U tray; expandable to 32.4 TB per RAID array |
FC Tray (12 HDDs) and FC/SATA RAID Array (108 HDDs) Maximum Raw Storage Capacities |
12x300 GB FC + 96x500 GB SATA |
51.6 TB max per RAID array. FC & SATA expansion trays may be mixed |
RAID Controller Card |
RAID configurations |
Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers |
|
RAID levels |
0, 1, 1+0, 3, 5, 3+0, and 5+0 |
|
Max. LUNS |
Up to 1,024 per RAID array |
|
Max. LUN sizes and max. number of logical drives |
Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max. Firmware 4.11 and above: Max. 16 TB LUN size; 32 logical drives max. |
|
Max. local and/or global hot spares |
Up to 20 (RAID set and disk quantity dependent) per RAID array |
|
Cache size (read and write) |
1 GB per controller |
|
Cache battery backup |
Up to 72 hours |
|
Cache write policy |
Write Back—default; Write Through—user configurable |
|
Cache selectable block sizes |
32K (random file transfer); 128K (sequential file transfer) |
|
Included Management software |
Sun StorageTek Configuration Service software; Sun StorageTek support Diagnostic Reporter software |
|
Optional supported software |
Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites |
Supported Host Platforms |
Supported Host Servers |
All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers |
|
Supported host bus adapters |
- Sun Solaris (8, 9, 10): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
- Sun Solaris x86 10: X9279A (Sun Fire V20z and V40z servers)
- MS Windows/Red Hat Linux/Novell SuSE Linux/Novell Netware: QLA23XX 2 Gb FC PCI*
- HP-UX 11.0 and 11i: Emulex LP9XXX 2 Gb FC PCI* and compatible
- IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2 Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor |
Reliability, Availability, Serviceability (RAS) |
RAS |
- Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
- Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
- Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant cooling fans
- Local and global hot sparing
|
Electrical Requirements |
Wattage |
420W each (Dual Hot-Swap Redundant Power Supplies) |
|
AC Voltage |
100 to 240 VAC, single phase |
|
AC Power requirement |
90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz) |
|
AC Current per input |
100 to 240 VAC, 50 to 60 Hz, 5.0–7.1A |
|
DC Voltage |
–48 or –60 VDC, 18A |
|
DC Power requirement |
–36 to –75 VDC |
|
DC Current per input |
–48 or –60 VDC, 18A |
Environment |
Temperature |
- Operating: 5°C to 40°C (41°F to 104°F)
- Non-operating: –40°C to 65°C (–40°F to 149°F)
|
|
Humidity (non-condensing) |
- Operating: 10% to 90% relative to 38°C
- Non-operating: 0% to 90% relative to 27°C
|
|
Altitude |
- Operating: –30 m to 3048 m (–100 to 10,000 ft.)
- Non-operating: –30 m to 12,192 m (–100 to 40,000 ft.)
|
|
Shock |
- Operating: 5.0 G, 11-ms, half-sine
- Non-operating: 15.0 G, 11-ms, half-sine
|
|
Vibration |
- Operating: 0.2 G, 5–500 Hz, swept-sine
- Non-operating: 1.0 G, 5–500 Hz, swept-sine
|
|
Noise * |
- Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C. |
Regulations - Meets or exceeds the following requirements: |
Safety |
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003 |
|
Emissions |
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark |
|
Harmonics |
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001 |
|
Immunity |
CSIPR 24 EN 55024 |
|
Ruggedized |
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386 |
|
Restriction of Hazardous Substances |
European Union (EU) Directive 2002/95/EC, invoking the "lead-in-solder" exemption, Article 4(1) paragraph 7. |
Dimensions and Weight |
Dimensions (Height, Width, Depth) |
H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.) |
|
Weight (Fully Populated) |
22.7 kg (50 lb.) |
Warranty |
Two year |
Sun two-year standard warranty, (1st year on site, 2nd year return to depot) |
|
Service upgrades |
SunSpectrum service upgrades are available |