Sun StorageTek 3510 FC Array

Цена: по запросу
Наличие: Под заказ
Производитель:Sun
Sun StorageTek 3510 FC Array

The Sun StorageTek 3510 FC array delivers enterprise-class Fibre Channel RAID storage features and flexibility. The compact, super-rugged, rack-dense 2U, 2 Gb array is easy to deploy, manage, and expand, giving you new levels of simplicity and savings.

At A Glance

  • 2 Gb Fibre Channel architecture
  • 8 Fibre Channel ports, dual RAID controller configurations
  • JBOD storage expansion
  • Telcordia NEBS Level 3 certification
  • MIL-STD-810F air, land, and sea specification compliance
  • Up to 1024 logical unit numbers (LUNs)
  • Hardware LUN masking

Key Applications

  • Business financial
  • E-commerce
  • ERP
  • HPTC and grid computing
  • NEP Telco applications

Features and Benefits

With its intuitive management interface, this array is extremely easy to deploy, configure, manage, and monitor. Affordable enterprise-class features and functionality, such as dual hot-swap power and cooling, hot-swap redundant RAID controllers with mirrored cache, hot-swap disk drives, and dynamic LUN and capacity expansion, the Sun StorageTek 3510 FC Array is the standout array in its class.

Key Benefits

  • Primary storage 2U array
  • Enterprise-class features and performance
  • NEBS Level 3 certification AND MIL-STD-810F compliance
  • Powerful management tools and options

Features and Benefits

  • Move Up and Save in So Many Ways
  • Rugged Reliability for Higher Availability
  • Flexibility Pays Off
  • Cost-Effective Expandability
Standard Interfaces
Host interface 2 Gb Fibre Channel

Drives 3.5 in. low profile

Supported drives Dual-ported active- active 2 Gb Fibre Channel 73 GB 15k rpm; 146 GB 10k rpm, 146 GB 15k rpm, 300 GB 10k rpm

Maximum number of host ports Dual RAID controllers: 8x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays

Maximum cable length 250 m
FC Tray (12 HDDs) and FC RAID Array (108 HDDs) Maximum Raw Storage Capacities
73 GB HDDs 876 GB per 2U tray; expandable to 7.8 TB per RAID array

146 GB HDDs 1.7 TB per 2U tray; expandable to 15.7 TB per RAID array

300 GB HDDs 3.6 TB per 2U tray; expandable to 32.4 TB per RAID array
FC Tray (12 HDDs) and FC/SATA RAID Array (108 HDDs) Maximum Raw Storage Capacities
12x300 GB FC + 96x500 GB SATA 51.6 TB max per RAID array. FC & SATA expansion trays may be mixed
RAID Controller Card
RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 1,024 per RAID array

Max. LUN sizes and max. number of logical drives

Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16 TB LUN size; 32 logical drives max.

Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 1 GB per controller

Cache battery backup Up to 72 hours

Cache write policy Write Back—default; Write Through—user configurable

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorageTek Configuration Service software; Sun StorageTek support Diagnostic Reporter software

Optional supported software Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites
Supported Host Platforms
Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported host bus adapters
  • Sun Solaris (8, 9, 10): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20z and V40z servers)
  • MS Windows/Red Hat Linux/Novell SuSE Linux/Novell Netware: QLA23XX 2 Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2 Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2 Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor
Reliability, Availability, Serviceability (RAS)
RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0–7.1A

DC Voltage –48 or –60 VDC, 18A

DC Power requirement –36 to –75 VDC

DC Current per input –48 or –60 VDC, 18A
Environment
Temperature
  • Operating: 5°C to 40°C (41°F to 104°F)
  • Non-operating: –40°C to 65°C (–40°F to 149°F)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38°C
  • Non-operating: 0% to 90% relative to 27°C

Altitude
  • Operating: –30 m to 3048 m (–100 to 10,000 ft.)
  • Non-operating: –30 m to 12,192 m (–100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Non-operating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5–500 Hz, swept-sine
  • Non-operating: 1.0 G, 5–500 Hz, swept-sine

Noise *
  • Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C.
Regulations - Meets or exceeds the following requirements:
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances European Union (EU) Directive 2002/95/EC, invoking the "lead-in-solder" exemption, Article 4(1) paragraph 7.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)

Weight (Fully Populated) 22.7 kg (50 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available
Системы хранения данных RaidShop.ru © 2025